Chemtron is an ISO 9001: 2015 certified organization that is an important part of fastest growing industries such as Electronics. We offer a wide array of electronic products that finds extensive applications in transistors, vacuum tubes, integrated diodes and various orhers industrial tools. The salient attributes of these products are excellent performance, long service life, low power consumption, sturdy construction, corrosion proof and impeccable finish. This product range is stringently testified on various parameters to ensure best quality product delivery to our esteemed patrons.

Gas Chromatograph

Gas Chromatograph is suitably utilized in various industries for analyzing and purifying various compounds without decomposition procedure. This instrument is precisely designed by using the high grade quality materials along with the implementation of latest technologies in compliance with the international quality norms.

Gas Chromatograph consists of
  • Carrier gas inlet
  • Septum purge outlet
  • Vapourisation chamber
  • Column
  • Heated metal block
  • Glass liner
  • Rubber septum
  • Detectors






Features
  • Accurate outcome
  • Sturdiness
  • Low power consumption
  • Long service life
  • Corrosion resistant
  • Impeccable finish
  • Easy operation
  • Low maintenance

Applications
  • Pharmaceuticals
  • Chemical plants
  • Gas industries

Specifications of CSL GC
Outline :

The Gas Chromatograph is 24 Bit microcontroller based instrument with 40×4 alphanumeric LCD display with back light for Injector, Column Oven, Detector and all heated zones temperature indications. It has a built in 24 bit high resolution data integrator A/D board with sampling frequency up to 20 Hz. It is having injection system suitable for analysis of Gas sample and liquid samples on packed/capillary columns using Thermal Conductivity and Flame Ionization Detectors. The data system has complete control of instrument conditions. Complete runtime display of chromatograms, quantification of analysis. It has advance options of storage and processing analytical data.

What makes it affordable!

Chemtron has been designing low cost gas chromatographs for over a decade. Chemtron has team of highly skilled and experience R&D department which consists of chemists and engineer’s who have been developing these instruments specially for small scale industries, collage’s and educational institutional which could not afford these analytical instruments. The complete system is made in house which includes The complete instrument consisting of Detectors, Columns, Pneumatics, Chassis, Electronics and also the Data integration software and its 24 Bit A/D board.

Gas Mixtures CSL-MODEL No. – 1045 CSL-MODEL No. – 2045
Description (With Single Detector – PIP. FPD. ECD. HID. TCP or FID) Gas Chromatograph will have the facility of Pressure Regulator Valve / Pneumatics Mass flow controller integrators, Manual cooling oven. Operating sensitivity mode (Low / Medium / High). The data system will have facility of control of instrument conditions, display of Chromatograms, quantification of analysis and storage of analytical data. CSL-1045 Gas Chromatograph also having optional facility of Methanizer. manual sampling valve, split/split less injection port for FID for dedicated analysis. University /College/Educational, Etc. (With Dual Detector-Upgradable up to 3 Detector) Gas Chromatograph will have the facility of TCD protection circuit, oven heat protection, in built integrators for data acquisition system. CSL-2045 Gas Chromatograph also having optional facility of M.F.C. (Digital), Methanizer, manual gas sampling valve for ppm level analysis of CO & CO2, data system with PC Storage of Chromatogram. Up to 3 detectors with TCD in series with FID can be configured for natural Gas analysis, Dissolved gas Analysis (TOGA). DGA Analysis/Solvent Gas Analysis/Permanent Gas Analysis.
Detectors Single Dual up to 3
Injection System (Controlled from PC with Software common for all models) Single port (Dual Optional) Single/Dual with two packed columns and one 1 PTV with split/split less spot
Operating Temp. Range Ambient 350^C Ambient 350^C
Pressure Control System Pressure regulator for carrier as well as air and H2 for FID. Mass flow controller for carrier gas. Optional TCD Different Pressure regulators for the air and H2 for FID. Mass flow controller for carrier gas.
Column Oven Temp (Controlled from PC with Software) common for all models Ambient 350^C react rate of 6 minutes at 1C/min to 30C / min with 7 ramps Ambient 350^C with react rate of 4 minutes at 1oC/min to 30C /min with 7 ramps
Cooling Speed 350C to 30C in 10 mins. with manual control. 350C to 30C in 4 min with auto control.
Over Heat Protection Available Hardware / Software Available Hardware / Software
Temp. Programming Ambient to 350C with 1C/min to 30C/min with 7 ramps Ambient to 350C with 1C/min to 30C/min with 7 ramps
Optional Facility Methanizer for detection of CO at ppm level. 24 bit software with pc control with instrument conditions, display of chromatographs, quantification and analytical data. Methanizer for detection of CO at ppm level. 24 bit software with pc control with instrument conditions, display of chromatographs, quantification and analytical data.
Accessories Packed column silica gel / molecular sieve 13 x gas tight syringe, septa , carrier gas cylinders, 24 bit data integrator with PC and printer Packed column silica gel / molecular sieve 13 x gas tight syringe, septa , carrier gas cylinders, 24 bit data integrator with PC and printer
Weight 8KG 18KG

CSL detectors in GCs
Detector Type Support Gases Selectivity Detectability
Flame ionization (FID) Mass flow Hydrogen and air Most organic cpds. 100 pg
Thermal conductivity (TCD) Concentration Reference Universal 1 ng
Helium Ionization Detector( HID) Concentration Helium In organic Gases 50 Ppb
Electron capture (ECD) Concentration Make-up Halides, nitrates, nitriles, peroxides, anhydrides, organometallics 50 fg
Flame photometric (FPD) Mass flow Hydrogen and air possibly oxygen Sulphur, phosphorus, tin, boron, arsenic, germanium, selenium, chromium 100 pg
Photo-ionization (PID) Concentration Make-up Aliphatics, aromatics, ketones, esters, aldehydes, amines, heterocyclics, organosulphurs, some organometallics 2 pg


Download PDF


Yes! I am Interested

Gases

Engineering

Electronics

Gas Chromatograph

Gas Analyzers

Controlled Atomosphere Systems

Ripening





Member IndiaMART.com © Chemtron Science Laboratories Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Looking for Product Name ?

x

Send SMS Enquiry

*Please Enter Requirment

*Please Enter valid Mobile Number

*Please Enter Proper Name

deneme bonusu veren siteler
deneme bonusu veren siteler
deneme bonusu veren siteler