Gas Monitoring System



Gas Chromatograph
CSL Gas Chromatograph System sets the standard for reliable performance in wide range of applications. Both gas and liquid samples may be analyzed on this unit. Samples can be introduced via sampling valves or by syringe. A complete selection of valves for back flush, heart-cut via column switching, as well as series/by pass operations are available, up to three valves, manually or pneumatically actuated may be installed. Pneumatically actuated valves can be remotely operated. A heated valve housing is also available for high temperature gas/liquid analysis applications. System can be configured to various detectors such as TCD, FID, PID, ECD, FPD and HID. GC can be operated at temperatures from ambient to 450°. Temperature readout is displayed digitally with selector switches provided to set and read desired temperatures. System can be configured as per customer’s requirement.


Description Model No.
1045 2045 7045
Detector Single Dual (up to Three) Dual (up to Three)
Injection System (Controlled from PC with Software common for all models) Single Port (Dual optional application specific). Single or Triple Port with 2 packed column and 1 PTV with spli/splitless port. Dual or Triple Port with 2 packed column and 1 PTV with spli/splitless port.
Operating Temp. Range Ambient to 350°C Ambient to 450°C Ambient to 450°C
Pressure Control System Pressure regulator for Carrier as well as Air & H2 for FID Mass flow controller for Carrier gas. (Optional) TCD. Differential pressure regulator for Air & H2 for FID Mass flow controller for Carrier gas Electronic pressure controller for Air & H2/ Digital flow controller for Carrier gas flows with complete control from software.
Column Oven Temp (Controlled from PC with Software common for all models) Ambient to 350°C, reach within 6 min max. volume 4 Ltrs. enough for 2 packed column. Ambient to 450°C, reach within 4 min. max volume 6 Ltrs. enough for 2 packed column and 1 capillary. Ambient to 450°C, reach within 10 min. max volume 9 Ltrs. Can hold 2 packed columns and 1 capillary. (60 meter)
Cooling Speed 350°C to 50°C within 10 min. (Manual Control) 450°C to 50°C within 4 min. (Auto Control) 450°C to 50°C within 10 min. (Auto Control)
Over Heat Protection Available Hardware / Software Available Hardware / Software Available Hardware / Software
Temp Programming Ambient to 350°C (0.1°C/ min to 50°C/ min) with 7 ramps. Ambient to 450°C (0.1°C/ min to 50°C/ min) with 7 ramps. Ambient to 450°C (0.1°C/ min to 50°C/ min 20°C after 350°C with 7 ramps.
Optional Facility Methanizer, (For Detection of CO2 & CO in ppm level) 24 bit of software with PC having facility of control instrument condition, display of chromatogram, quantification of analysis and storage of analytical data. Methanizer, (For detection of CO2 & CO in ppm level) 24 bit of software with PC having facility of control instrument condition, display of chromatogram, quantification of analysis and storage of analytical data. Methanizer, (For detection of CO2 & CO in ppm level) cryogenic attachment for low temp (up to-99°C) application. Headspace sampler (HS) for batch analysis. Can be configured as per any standards such as ASTM or EPA methods with suitable dedicated software with analysis as per the method.
Accessories Packed column silica gel/ molecular sive 13 x Gas tight syringe, septa, Carrier gas Cylinders, 24 Bit data integrator & PC with printer. Packed column silica gel/ molecular sive 13 x Gas tight syringe, septa, carrier gas cylinders, 24 bit data integrator & PC with printer Porapack-Pack column/DC 200 pack column, Gas tight syringe, septa, carrier gas cylinders, 24 bit data integrator & PC with printer
Weight Approx 8 kg Approx 18 kg Approx 25 kg



Analysis of Natural Gas

Lab Name CSL Pvt. Ltd.
Detector TCD
Carrier N2
Column Porapak-Q
Sample Natural Gas
Vol. Inj. 1 ml
Temp Initial 40, Hold 2 min nal
180, Ramp 10

Analysis of Natural Gas



Gas Analyzers
CSL manufactures range of gas analyzers like flue gas analyzers and bio gas analyzers, user friendly hand held gas detectors. The detectors are low cost, light weight, battery operated, these units has been indigenously designed for Indian conditions.

These analzers are broadly classified as: Typical Measurement Ranges Salient Features
Send Enquiry



Bio- Gas Analyzer

  Bio- Gas Analyzer
Operating Temperature 0° C to 45°C (± 1°C)
Humidity 0 to 90 % approx (Non – Condensing )
Power Source Rechargeable 10 Volts Battery
Display Back Light Liquid Crystal Display
Alarm Output ( With adjustable set point)
Audible Indicated by audible beeper
Visual Flashing display on LCD
Sensor H2, S, O2 – Electrochemical & CO2, HC – IR Sensor
Range H2S, : 0-2000 ppm O2 : 0-25.0 %
CH4 : 0-100% CO2 -100%
Resolution For H2S 10 ppm, 02 0.1 % & for other sensors 1%
Accuracy ± 5%
Bio- Gas Analyzer



Applications




Send Enquiry



Flue Gas Analyzers

  Flue – Gas Analyzer
Operating Temperature 0° C to 45°C (± 1°C)
Humidity 0 to 90 % approx (Non – Condensing )
Power Source Rechargeable 10 Volts Battery
Display Back Light Liquid Crystal Display
Alarm Output ( With adjustable set point)
Audible Indicated by audible beeper
Visual Flashing display on LCD
Sensor H2S, NO2, SO2, Co- Electrochemical & CO2, HC – IR Sensor
Range H2S, : 0-2000 ppm SO2 : 2500 ppm
NO2 : 0-200 ppm CO2 : 0-100%
CO 0-2000 ppm CH4 : 0-100 %
Resolution For H2S 10 ppm, 02 0.1 % & for other sensors 1%
Accuracy ± 5%


Send Enquiry




Ethylene Ripening System* New
Ethylene Ripening System
This is the specialized product which consists of CO2 analyzer, ethylene analyzer with concentration controller, doping ethylene gas cylinder, regulator along with fully automatic concentration controller solenoid valves and dispensing pipeline. This fruits or the commodity (raw or partially ripe) is placed inside a closed chamber where the environment is controlled from temperature, humidity, ethylene and co2. The ripening process of fruits is accelerated in this chamber because of ethylene gas mixt in the chamber. Hence this system expedites ripening of fruits in few hours rather than weeks. Also the color, taste of the ripened fruits is much better compared to natural ripening.

Advantages Applications

Send Enquiry

Data Integration Software



CSL gas chromatographs are equipped with build in data processor. The data processor collects the analog signal from detector and displays the chromatogram on the Pc’s monitor scree. Peak area / peak height and retention time is displayed on report. The peak can be integrated automatically or manually and complete Report can be manipulated locally from the gas chromatograph as well as from the software Temperature programming can be done from the software which can incorporate up to 10 temperature with a time span of up 2 hours. All chromatographic controls can be controlled using the software such as flame on/off, TCD current high / low etc.
Send Enquiry