Chemtron Science Laboratory offers a simple
inexpensive Unit MODEL Chemtron Science Laboratory: DGA-492 for
Transformer Oil Dissolved Gas Analysis.
The System consists of Gas Extraction Unit.
To extract the Gas from the Transformer Oil. The Oil is stirred during
Extraction under vacuum at a Temperature of 80 to 90°C by employing a
magnetic stirrer. The volume of Gas is measured.
The MODEL Chemtron Science Laboratory:
DGA-492 is specially tailored for this Analysis. It consists of FID and
TCD Detectors with suitable columns such that Methane, Ethane, Ethylene,
etc are separated out and detected by FID, CO and CO2 is converted into
Methane by Methanator Unit and detected by FID. Hydrogen is detected
through TCD using Argon as Carrier Gas. With unique System Design and
Integration Software the whole operation and complete Analysis is
completed in 15 minutes. Calibration Gas standards required for the Unit
comes in two mixtures one having Hydrocarbons and the other having
Hydrogen CO and CO2.
Chemtron Science Laboratory offers complete
System with Calibration Gas, Carrier Gas alongwith Gas Extraction Unit
and Chromatographic Unit we also undertake the Analysis of DGA in our
Lab.
|